Software | Dewesoft Forum
5 days ago · Software. Can you input a multi-point calibration on a counter input? Exporting data with wrong absolute time. Clarity regarding the motor analysis tool. Questions and community discussions about dewesoft data acquisition systems: SIRIUS, KRYPTON, IOLITE, IOLITEd, dewe-43A, and DS-MINITAURs.
Forum.dewesoft.comWiring diagrams for analog sensors pressure and temperature
Jan 20, 2020 · I am trying to connect a absolute pressure sensor to the analog input pin connector on the dewe 43. The pressure sensor has a 4 pin M12 male connector with a 0- 5 V voltage output. I am unable to figure out how to connect the sensor to the 9 pin D-sub female connector on the dewe 43 for analog inputs.
Forum.dewesoft.comForum Discussions | Dewesoft Forum
5 days ago · dewesoft Instruments. Questions and community discussions about dewesoft data acquisition systems: SIRIUS, KRYPTON, IOLITE, IOLITEd, dewe-43A, and DS-MINITAURs. 95 topics. 301 replies. Connecting Omega Hot Wire Anemometer to STG. Last post by Pika Kreča Šmid. Posted at 10.10.2024 08:44. dewesoft Accessories.
Forum.dewesoft.comSetting up interface Load cell with DEWE-43A - Dewesoft
Sep 21, 2021 · In the datasheet, it is stated only the maximum allowed voltage (20V) and no lower limit. dewe-43 can output max 12V and 350 mA. This power is shared between all the channels. If the sensor is too powerful for the dewe-43 to supply it an additional power supply will be needed. The EXC and SNS lines can also be used instead of the +12V, but they
Forum.dewesoft.comDewe-101 Minitaur Questions | Dewesoft Forum
Sep 28, 2017 · Hi, in regards to point 1, 12 V is enough to power up a dewe-101. The minimum required voltage is 6 V, of course, measured on the contacts of the connector to account for the voltage drop, so the inverter is not necessary.
Forum.dewesoft.comHow to connect pressure sensor to DEWE-43? - Dewesoft
Jul 19, 2019 · C: -ve output. D: -ve supply. E&F: Shunt calibration. Dear Khushi Singh, we would recommend using the connection option shown below because the dewe43 has a 12V / 400mA sensor supply. The sensor should be connected like defined on the picture. For the sensor to work properly a scaling has to be made.
Forum.dewesoft.comSynching Dewe-43s | Dewesoft Forum
Oct 4, 2012 · BUT, there is no information in the dewe-43 or the dewesoft 7 manuals about synching two devices. Mostly it's obvious: a) connect both dewe-43s to the pc using usb cables. b) connect the dewe-43s together with the sync cable c) select hardware-setup/analogue Analogue device = deweSoft USB d) go to the analogue Ch Setup screen and 16 channels
Forum.dewesoft.comConnecting Full Bridge Strain Gauge to the DEWE-43A
Jun 29, 2023 · Hello, what is the full setup for a full bridge type 3 setup httpswww.ni.comdocsenUSbundlelabviewwirelesssensornetworkmodulepageniwsnhelpfull3.html. I have 120
Forum.dewesoft.comUsing excitation voltage from DEWE-43a for Honeywell pressure …
Apr 8, 2023 · Looking at the dewe-43a manual and several answers on this forum, I see that its excitation voltage is fixed at +/- 5V, which is too much for our Honeywell sensor. I was wondering if this was always true? And, if there actually is a way to change the excitation voltage of the dewe-43a, could you please provide it to me?
Forum.dewesoft.comDigital out via sync port Dewe-43 | Dewesoft Forum
Jan 19, 2021 · Digital out via sync port dewe-43; Anders Ingemansson. Posted on 19.01.2021 12:18. Login to reply. Hello.