Can different gauges of wire be used on the same circuit?
Jun 21, 2023 · Circuit Breakers and fuses protect wire, not equipment. The reason is heat. A heavier gauge wire can carry more electricity and stay cooler. On my sailboat's AC circuits, I ran 10 Gauge on my 20 amp circuits and 12 gauge on my 15 amp circuits. Part of the reason I do this is because I am bundling wires along the same path.
Diy.stackexchange.comPracticality of adding 3-phase power to residence?
Jun 10, 2017 · The older old 230 3 phase was the worst to work with and bring up to code. The 480 was easier as we set up a 120-240 transformer for the residence itself. In some areas it can be done but there is no savings on the power bill if you look at the cost for the initial install unless the equipment is +25 HP from what I have seen. –
Diy.stackexchange.comCan I backfeed a portable generator into my house's electrical …
You can use the breakers to power one device at a time, fridge for a few hours, then the hot water, etc. And when the water is hot and fridge is cold, shutoff the generator to save gas and leave the fridge closed to keep it cool. Only other piece of advice I can think of is to make sure the exhaust is properly vented.
Diy.stackexchange.comelectrical - Can I do two 220V on a single line? - Home …
Yes. You can put as many receptacles as you like on a circuit in residential applications. 240 volt receptacles only require 2 wires and a ground wire. Hence the 12/2 wire is sufficient. Circuits are required to be sized for the load they serve. Continuous loads are required to be sized at 125% of the load served.
Diy.stackexchange.comelectrical - Can I use 10 gauge wire off of a 20 amp breaker?
5. Can I use 10 gauge wire off of a 20 amp breaker for outlets, lights or a window unit? I am wiring a barn and have a lot of 10/3 wire I would like use up. I'll just comment that you are NOT going to be happy working with #10 in device boxes. Your sanity will be worth the cost of a roll of 12/2. Also, be careful with regard to box fill.
Diy.stackexchange.comelectrical - annoying vibration, deep humming noise in home
Nov 12, 2015 · 1. I am experiencing noise and vibration in my home. I purchased a seismometer (infiltec) that shows there is vibration (below 20 hz). The software allows fast fourier transform giving frequency signature. This tool has limitations in that it is not calibrated and it only detects vibration below 20hz.
Diy.stackexchange.comHow can I provide adequate power to my 120V welder?
Feb 14, 2024 · It seems that I could put another outlet on that circuit and flip it around into the garage (same wall) and have the amps I want. The other suggested 14-50 looks compelling too - I see an adapter on Amazon which will take a 14-50 and give you 4 outlets (2 pairs out of each phase). electrical. welding. 120v.
Diy.stackexchange.comCan structural bricks be used as pavers for a patio?
Mar 4, 2020 · For 9 rows by 11 columns, the total cost was over $1000 for all the pavestones, the gravel paver base, leveling sand, polymeric joining sand, tamper, and edging/spikes. The "brick" pavers are much cheaper, though typically they start at $1.50, not $0.50. – TylerH. Mar 4, 2020 at 22:56. Show 3 more comments.
Diy.stackexchange.comType of exterior door lock that always allows exiting?
Nov 4, 2021 · 5. This type of lock is usually commercial, and it's called a storeroom lock. They typically have a keyed lock on the outside and no access control on the inside. The inside is always unlocked so you can't trap someone in a closet, but the outside can be locked or unlocked with a key (and only the key). Here is example of one lock from a random